PDUBHV10 - 2-2.4kW Single-Phase Hot-Swap PDU, 200-240V 10A Outlets (8-C13), 2-C14, 200-240V Input, 6ft Cords 2U Rack-Mount

To see an accurate total, please select your payment method

Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads. Dual input power cables support PDU connection to separate Utility and UPS power sources.
Manufacturer: Tripp Lite
Call for pricing

Features

  • 2U horizontal rackmount form factor compatible with 2 or 4 post racks
  • 8 C13 outlets support critical networking loads in both Utility and UPS operating modes
  • Dual input power cables support PDU connection to separate Utility and UPS power sources
  • Hot-swap PDU systems support live-replacement of standard UPS systems
  • Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
  • Once the new UPS is up and running with all connections restored, set the switch back to the UPS setting
  • One additional C13 pass-through outlet supports UPS input power cord
  • Pair of attached 5-20P PDU input cables connect to separate Utility and UPS power sources
  • PDUBHV10 is universally compatible with any brand of 200-240V UPS rated up to 1500VA
  • Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
  • Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power
  • Supports space saving rear-post mounting in the same rack space as many rackmount UPS systems

Features

  • 2U horizontal rackmount form factor compatible with 2 or 4 post racks
  • 8 C13 outlets support critical networking loads in both Utility and UPS operating modes
  • Dual input power cables support PDU connection to separate Utility and UPS power sources
  • Hot-swap PDU systems support live-replacement of standard UPS systems
  • Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
  • Once the new UPS is up and running with all connections restored, set the switch back to the UPS setting
  • One additional C13 pass-through outlet supports UPS input power cord
  • Pair of attached 5-20P PDU input cables connect to separate Utility and UPS power sources
  • PDUBHV10 is universally compatible with any brand of 200-240V UPS rated up to 1500VA
  • Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
  • Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power
  • Supports space saving rear-post mounting in the same rack space as many rackmount UPS systems
Products specifications
Cord Length (in/mm) 72 in
Maximum Input Amps 10
Products specifications
Cord Length (in/mm) 72 in