On-line double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 19-inch.
Manufacturer: Tripp Lite
Call for pricing

Features

  • Compact rackmount form factor installs using only 2 rack spaces (2U) with maximum installed depth of only 19-inch
  • Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 100/110/120V (+/-2%) values
  • Extended runtime available with optional BP48V24-2U (limit 1) or BP48V60RT3U (no limit) external battery packs
  • Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs
  • Ideal for critical voice, data, medical and industrial network applications
  • Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
  • Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
  • Some external battery configurations require the use of Tripp Lite's external battery configuration software
  • Standard internal battery set offers 14 minutes runtime at half load (600W) and 5 minutes at full load (1200W)
  • True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all usage conditions

Features

  • Compact rackmount form factor installs using only 2 rack spaces (2U) with maximum installed depth of only 19-inch
  • Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 100/110/120V (+/-2%) values
  • Extended runtime available with optional BP48V24-2U (limit 1) or BP48V60RT3U (no limit) external battery packs
  • Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs
  • Ideal for critical voice, data, medical and industrial network applications
  • Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
  • Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
  • Some external battery configurations require the use of Tripp Lite's external battery configuration software
  • Standard internal battery set offers 14 minutes runtime at half load (600W) and 5 minutes at full load (1200W)
  • True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all usage conditions
Products specifications
Battery Half Load Runtime 14
DC Battery System Voltage 48
Estimated Runtime 5
Operating Temperature (Maximum) 40
Operating Temperature (Minimum) 32
Output kVA Capacity 1.5
Output volt amp capacity 1500
Output Watt Capacity 1200
Rated input current (at maximum load) 12
Products specifications
Battery Half Load Runtime 14
DC Battery System Voltage 48
Estimated Runtime 5
Operating Temperature (Maximum) 40
Operating Temperature (Minimum) 32
Output kVA Capacity 1.5
Output volt amp capacity 1500
Output Watt Capacity 1200
Rated input current (at maximum load) 12