Search
Filters

SU10000RT3U2TF - SmartOnline 208/120V 10kVA 9kW Double-Conversion UPS, 10U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch,NEMA

To see an accurate total, please select your payment method

10kVA online double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications.
Manufacturer: Tripp Lite
Call for pricing

Features

  • Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
  • Expandable runtime is supported with optional BP240V10RT3U, BP240V557C-1PH, BP240V787C-1PH, BP240V1037C-1PH, BP240V1407C-1PH external battery packs
  • Fault tolerant electronic bypass maintains utility output during variety of UPS fault conditions
  • Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
  • Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs
  • Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V
  • Maximum installed rack depth of only 32.5-inch (82.6cm)
  • PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted
  • Some external battery configurations require the use of Tripp Lite's external battery configuration software

Features

  • Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
  • Expandable runtime is supported with optional BP240V10RT3U, BP240V557C-1PH, BP240V787C-1PH, BP240V1037C-1PH, BP240V1407C-1PH external battery packs
  • Fault tolerant electronic bypass maintains utility output during variety of UPS fault conditions
  • Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
  • Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs
  • Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V
  • Maximum installed rack depth of only 32.5-inch (82.6cm)
  • PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted
  • Some external battery configurations require the use of Tripp Lite's external battery configuration software
Products specifications
Battery Full Load Runtime 4.3
Battery Half Load Runtime 12.5
DC Battery System Voltage 240
Estimated Runtime 4.3
Frequency Compatibility 60
Nominal Input Voltages Supported 208
Operating Temperature (Maximum) 40
Operating Temperature (Minimum) 32
Output kVA Capacity 10
Output volt amp capacity 10000
Output Watt Capacity 9000
Rated input current (at maximum load) 54
Products specifications
Battery Full Load Runtime 4.3
Battery Half Load Runtime 12.5
DC Battery System Voltage 240
Estimated Runtime 4.3
Frequency Compatibility 60
Nominal Input Voltages Supported 208
Operating Temperature (Maximum) 40
Operating Temperature (Minimum) 32
Output kVA Capacity 10
Output volt amp capacity 10000
Output Watt Capacity 9000
Rated input current (at maximum load) 54